UF2e-6034
125 MS/s 2 ch. or 60 MS/s 4 ch. 14-bit Arbitrary Waveform Generator, PCI Express
- Filter bandwidths of 25 MHz, 5 MHz or 500 kHz
- Synchronous generation on all channels
- 128 MSample to 2 GSample on-board memory
- Streaming at up to 120 MB/s from host PC
- Max. output range: ±3V into 50 Ohm
- Amplifier option increases output to ±10V
- Programmable offset and amplitude
- Multiple Replay option for RADAR applications
- Up to 271 cards can be synchronized
- SDK's for Windows, Linux, VxWorks and third-party programs
Overview
The UF2e Arbitrary Waveform Generator (AWG) cards are used as lower cost, more flexible and deeper memory alternatives to standalone instruments. The Strategic Test cards are designed to offer maximum versatility, ease of programming, highest fidelity generation, long-term reliability and low power consumption. Manufactured in Germany the instrument cards include a two year hardware warranty combined with lifetime technical support and software updates - which includes new drivers for future operating systems and third-party software.
Analog Outputs
The UF2e-6034 Arbitrary Waveform Generator card allows you to generate complex analog signals with output rates from 1 kSamples per second to 125 MSamples per second on 2 channels, or 60 MS/s on 4 channels. All channels have separate 14-bit DAC's that are synchronized by a common clock for output without phase-errors. Each channel can be configured with one of the three available low-pass filters, or you can choose to select the no-filter option. In addition, each channel has independent dcV offset adjustment.
There are two other output features: Differential Output and Double-Out mode. The Differential output generates the data on even channels and inverted signals on the odd channels. This generates differential signals that are more noise resistant when transmitted over long cables. The Double-Out mode is similar but outputs the same signals on both even and odd channels.
Deep Signal Memory and Streaming to the PC
The AWG comes with 256 MBytes signal memory that can be expanded at the factory in increments up to 4 GBytes. Like all of the Strategic Test waveform generator cards there are two operating modes. In Standard mode the data to be generated is first stored to the onboard memory. Output is started on software or external TTL trigger and the signal(s) are output once, n times, or repeated until the card is stopped by software. This mode allows the cards to output at the maximum clock rate. While generating, the card operates independently of the host PC so the cpu can be used for other tasks.
Alternatively, the FIFO mode allows data to be continuously transferred from the PC to the AWG card during the output, so that much longer signals than the onboard memory can be generated. However, the PCI Express x1 bus has a maximum continuous transfer rate (not to be confused with Burst Transfer which is higher) of approximately 120 MBytes/s - so this effectively limits the maximum output rate during streaming to approximately 60 MS/s when using 14-bit (2 Byte) resolution.
Unlike older the PCI and PCI-X bus where the bus is shared, PCI Express x1 has the advantage that every slot has a maximum continuous transfer rate of up to 120 MBytes/s. This means if four digitizer cards are installed, that the total system transfer rate is up to 480 MBytes/s. Note that the limit of 120 MBytes/s is determined by current motherboards; the UF2e card is able to transfer up to 160 MBytes/s.
Sampling Clock
Unlike other Arbitrary Waveform Generator cards that offer a limited choice of fixed output rates, the UF2e cards allow you to set an output rate with a fine degree of accuracy by using one of the six different modes available that use a combination of internal 10 MHz reference clock, PLL, hardware divider, quartz clock, external reference clock and external clock. There is also a factory option to install a second quartz for applications that require highest accuracy and stability at a customer-specific output rate. The external clock connector can be programmed as either an input or as an output when you want to synchronize external equipment.
Flexible Triggering
In addition to the standard external TTL trigger, the XBaseIO option can be used to AND/OR two more external trigger inputs.
The External Trigger connector can be set to either input or output when you need to synchronize the start of measurement with external equipment.
Synchronization
The Star Hub option is available in two versions that synchronize the clock and trigger signals of either up to 5 cards or 16 cards within the PC. All analog outputs will be perfectly synchronized with no phase error between channels. It's also possible to configure mixed mode systems that contain a mixture of digitizer, arbitrary waveform generator and high-speed digital I/O instrument cards.
This option only needs to be purchased for one card in the system and consists of a small daughterboard that is factory-installed to the card. The clock and trigger signals are then distributed by small ribbon cables to this and the other cards. The 16 card version being larger in size does require an additional PCI slot width.
For larger configurations, the System Star Hub option allows up to 271 cards to be synchronized by distributing the clock and trigger signals across up to 17 PC's.
Advantage of PCI Express for instrumentation
Read an application note on the advantages of PCI Express here .
Applications
Typical applications include: I&Q, ATE, RADAR, video
What's Included?
We believe that the Strategic Test instrument cards offer the best price vs performance and lowest cost-of ownership available. The following items are included:
- 256 MByte onboard memory
- +100 page printed user manual
- SDK's for Microsoft Windows and Linux
- Example source code programs for Visual Basic, Visual C++, Borland C++ Builder, Gnu C, Borland Delphi, VB.NET, C#, J#
- SBench measurement and generation program
- Two year hardware warranty, optional 5 years
- Lifetime technical support
- Lifetime updates for Windows and Linux SDK's, including future versions
- Lifetime updates for optional third-party drivers (if purchased), also future version releases
Specifications
General
| Name | Value |
|---|---|
| Bustype: | PCI Express |
| OS support: | Linux 2.4, Linux 2.6, VxWorks, Windows 2000, Windows Vista, Windows XP, |
| Program examples: | C#, C++, DELPHI, J#, VB, VB.NET, |
| Software: | SBench 5.0, SPEasyGenerator, |
| SDK | DASYLab, LabVIEW, LabWindows/CVI, Matlab, VEE, |
| SDK examples: | Yes |
Operating Modes
| Name | Value |
|---|---|
| Standard | Transfer data to card memory, output once or continuous |
| FIFO | Continuous streaming from host PC up to 120 MB/s |
Analog Output
| Name | Value |
|---|---|
| Number of Channels | 4 SE |
| Resolution | 14 bit |
| Maximum Sample Rate | 125 MS/s 2 ch. or 60 MS/s 4 ch. |
| Synchronous Outputs | Yes |
| Memory | 128 to 2048 MSamples |
| Maximum Voltage in 50 Ohm | +/-3 V |
| Sensitivity | 36.6 uV |
| Maximum Slew Rate (no filter) | > 0.9 V/ns |
| Crosstalk 1 MHz signal, +/-3 V | < -80 db |
| Output Accuracy | < 1 % |
| Output Resistence | < 1 Ohm |
| Connector | 3 mm SMB male |
Dynamic Parameters
| Name | Value |
|---|---|
| Bandwidth, no filter | > 60 MHz |
| Filter 3, 5th order Butterworth | 25 MHz |
| Filter 2, 4th order Butterworth | 5 MHz |
| Filter 1, 4th order Butterworth | 500 kHz |
| Signal to Noise Ratio (SNR) | > 61.5 dB |
| Total Harmonic Distortion (THD) | < -71.5 dB |
| Spurious Free Dynamic Range (SFDR) | > 82.8 dB |
Clock
| Name | Value |
|---|---|
| Internal Clock Range | 1 kS/s to 125 MS/s |
| External Clock Range | DC to 125 MS/s |
Trigger
| Name | Value |
|---|---|
| Re-arming time: MR, GR options | < 4 samples |
| External trigger type | TTL |
| Trigger output delay | 1 positive edge after internal trigger event |
Power consumption
| Name | Value |
|---|---|
| With 256 MBytes memory (max speed), 3.3 V | 0.4 A |
| With 256 MBytes memory (max speed), 12 V | 1.2 A |
Physical specifications
| Name | Value |
|---|---|
| Dimensions, PCB only | 312 mm x 107 (full PCI length) |
| Width | 1 full size slot |
| Width, inc. Star Hub or Digital Outputs options | Two full size slots |
| Weight, standard card | 290 g |
Options
Application options
| Prodnr | Name | Desc |
|---|---|---|
| UF2-6000-mr | Multiple Replay | The Multiple Replay option allows a fast series of waveforms to be generated on external trigger events without restarting the signal generator board. This is often used to generate a series of high-speed waveforms that occur at a very high repetition rate, such as RADAR, Lidar or spectroscopy signals. Factory or user installed option. |
| UF2-6000-gr | Gated Replay | The Gated Replay option allows waveform generation controlled by an external gate signal. Data is only output if the gate TTL signal changes to the active level. Factory or user installed installed option. |
| UF2-6000-dig | Digital Outputs | The Digital Outputs option adds high-speed digital channels that can be generated synchronously with the analog signals. Factory installed option. |
| UF2-6000- | ||
| UF2-6000-1amp | 1 channel Amplifier PCI card for AWG instruments | Single channel Amplifier PCI card increases the standard output of the Arbitrary Waveform Generator cards from ±3V up to ±10V. |
| UF2-6000-2amp | 2 channel Amplifier PCI card for AWG instruments | Dual channel Amplifier PCI card increases the standard output of the Arbitrary Waveform Generator cards from ±3V up to ±10V. |
| UF2-6000-4amp | 4 channel Amplifier PCI card for AWG instruments | Quad channel Amplifier PCI card increases the standard output of the Arbitrary Waveform Generator cards from ±3V up to ±10V. |
| UF2-6000- | ||
| UF2-6000-sh16 | Star Hub option for synchronizing up to 16 UF2-series cards | This Star Hub option allows up to 16 instrument cards to be synchronized by sampling clock and trigger to obtain simultaneous sampling across all channels. Factory installed option. |
| UF2-6000-sshm | System Star Hub Master | Using the System Star Hub Master option it’s possible to synchronize Star Hub Slave systems in up to 16 host PC’s. Each PC can contain up to 16 cards (Master only 15), making a total of 271 instrument cards that can be fully synchronized. One Master system distributes clock and trigger signal to all connected Slave systems. Factory installed option. |
| UF2-6000-ssh5 | System Star Hub Slave for synchronizing up to 5 cards | This version of the System Star Hubs Slave option allows up to 5 instrument cards in the same PC to be synchronized. This option is used together with the System Star Hub Master option to synchronize instrument cards in multiple PC's. User installed option. |
| UF2-6000-ssh16 | System Star Hub Slave synchronizes up to 16 cards | This version of the System Star Hubs Slave option allows up to 15 instrument cards in the same PC to be synchronized. This option is used together with the System Star Hub Master option to synchronize instrument cards in multiple PC's. User installed option. |
Cables
| Prodnr | Name | Desc |
|---|---|---|
| Cab-3f-9m-80 | SMB female to 9mm BNC male 80 cm | For analog inputs and outputs, external clock and external trigger |
| Cab-3f-9m-200 | SMB female to 9mm BNC male 200 cm | For analog inputs and outputs, external clock and external trigger |
| Cab-3f-9f-80 | SMB female to 9mm BNC female 80 cm | For analog inputs and outputs, external clock and external trigger |
| Cab-3f-9f-200 | SMB female to 9mm BNC female 200 cm | For analog inputs and outputs, external clock and external trigger |
| Cab-3f-3f-80 | SMB female to SMB female 80 cm | For external clock and external trigger |
| Cab-3f-3f-200 | SMB female to SMB female 200 cm | For external clock and external trigger |
| Cab-3f-3f-5 | SMB female to SMB female 5 cm | For oscilloscope probes |
| Cab-d40-idc-100 | Flat ribbon cable, FX2 connector to IDC | Cable for high-speed Digital cards and the Digital Input and Digital Output options |
| Cab-d40-d40-100 | Flat ribbon cable, FX2 connector to FX2 | Cable for high-speed Digital cards and the Digital Input and Digital Output options |
Software
| Prodnr | Name | Desc |
|---|---|---|
| SBench 5.0 | ||
| SPviewIT-mlt | SPEasyGenerator |